DragonFly kernel List (threaded) for 2010-04
[
Date Prev][
Date Next]
[
Thread Prev][
Thread Next]
[
Date Index][
Thread Index]
Re: I/O errors on Hammer volume
On Tue, Apr 13, 2010 at 11:49:03AM -0700, Matthew Dillon wrote:
>
> :I have included the most relevant part of the output of
> :"smartctl -d sat -a /dev/da0" below:
> :
> :SMART Attributes Data Structure revision number: 16
> :Vendor Specific SMART Attributes with Thresholds:
> :ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
> :..
> :193 Load_Cycle_Count 0x0032 147 147 000 Old_age Always - 160820
> :
> :--
> :Francois Tigeot
>
> Another thing you can do is run 'hammer -f <device> show | less -B'
> and search for lines beginning with the character 'B'. You would
> type slash-carrot-B into LESS. The hammer show command checks
> for problems.
There are many such lines. I have copied the first few ones:
BM NODE 800000268ea27000 cnt=33 p=800000268ea12000 type=L depth=4 mirror
000000013a77e4d0 fill=z8:19741=60% {
BM NODE 800000268ea31000 cnt=33 p=800000268ea12000 type=L depth=4 mirror
0000000139b6e140 fill=z8:19741=60% {
BM NODE 800000268eb0e000 cnt=32 p=800000268eb02000 type=L depth=4 mirror
0000000148774380 fill=z8:19741=60% {
BM NODE 800000268eb19000 cnt=32 p=800000268eb02000 type=L depth=4 mirror
0000000139b6e840 fill=z8:19741=60% {
--
Francois Tigeot
[
Date Prev][
Date Next]
[
Thread Prev][
Thread Next]
[
Date Index][
Thread Index]