On Tue, Apr 13, 2010 at 11:36:40AM +0200, Michael Neumann wrote:
> 2010/4/13 Francois Tigeot <ftigeot@wolfpond.org>
>
> > These directories can no longer be used:
> >
> > # cd /usr/pkg
> > # ls -ld o*
> > ls: openoffice.org: Input/output error
> > ls: openoffice.org3: Input/output error
> >
> > Is there any tool I can use to diagnose and fix this problem ?
>
> Check with sysutils/smartmontools. I'd love to have a simplistic SMART
> monitoring daemon integrated into DragonFly which is run by default.
> This would be so cool and useful!
Thanks, this could be a very nice utility but I'm afraid the output is bit too
cryptic for my tastes.
I have included the most relevant part of the output of
"smartctl -d sat -a /dev/da0" below:
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0
3 Spin_Up_Time 0x0027 157 148 021 Pre-fail Always - 3116
4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 135
5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
7 Seek_Error_Rate 0x002e 200 200 000 Old_age Always - 0
9 Power_On_Hours 0x0032 097 097 000 Old_age Always - 2218
10 Spin_Retry_Count 0x0032 100 100 000 Old_age Always - 0
11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 133
192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 131
193 Load_Cycle_Count 0x0032 147 147 000 Old_age Always - 160820
194 Temperature_Celsius 0x0022 109 093 000 Old_age Always - 34
196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0030 200 200 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline - 0
--
Francois Tigeot
[